CO2 fractional interface
Technical Data
Maximum analog fractional input: 65536 (point)
 
Adjustable range of point signal: 0~2.56V, 0~5V, 0~10V 【±2.56V, ±5V, ±10V (optional)】
 
Scanning angle of motor: ±20°(The angle is changeable according to different requirements)
 
Ration coefficient of point area is adjustable based on focus: 2.56V (57600points)/2.5cm
 
Scanning shape: straight line, square, rectangle, triangle, regular hexagon, circle and oval.
The size of all the shapes can be adjusted and the adjustable unit is 1mm.
 
Scanning mode: in disorder, in order, in maximum distance between point to point.
 
Input voltage: ±24VDC
 
Maximum peak current: 5A; Average current: 1.5A
 
Protection signal time of laser cutting off: 0.03ms
 
Protection time of system failure: 0.09ms
 
Linearity: 99.9%
 
Load mirror: Spot less then 10mm
Consultation 